Data Center: SNA1

Located at 1400 South Grand Avenue in Orange County, VPLS has partnered with ACS, a Xerox company, to offer customers the most state-of-the-art facility in Southern California.

About the SNA1 Data Center

Boasting over 65,000 square feet of raised, ventilated flooring and other amenities, our fully redundant facility was designed to be safe and secure.

Data Center Location

Santa Ana Data Center (SNA1)
1400 South Grand Avenue
Santa Ana, CA 92705

Other VPLS Data Center Locations

In addition to our Santa Ana data center, we’ve got California covered. With VPLS you can directly connect to the rest of our national and global data centers.

SNA Technical Specifications

Security

  • 24×7 multiple-layer security access
  • 24×7 infrastructure and perimeter monitoring
  • 24×7  Key card access /Mantrap
  • 24×7  external building monitoring by highly sensitive and state of the art microwave beams
  • 24×7 surveillance camera monitoring

Interconnection

  • Directly connect to world-class network carriers and partners through Fiber, Ethernet, COAX, or POTS.
  • AT&T
  • CenturyLink
  • Cogent
  • Level3
  • Paxio
  • Verizon
  • XO
  • Zayo
  • Dark Fiber to EQX1

Space & Environmentals

  • 65,000 square feet
  • Equipped with air filtration and cooling systems, backup power and utilities, fire suppression, earthquake preparedness, and physical security
  • Halon 1301 Fire Suppression system
  • 33,000 square feet of raised floor space design
  • 22,000 volt power feeds from redundant Edison circuits
  • Dual Liebert 750kVA UPS battery backup N+1 design with over 480
  • 12,500 gallons of diesel fuel on site

Global Footprint

  • Network Dense Platform
  • Average Of 15 Carriers Per Site
  • 100+ Unique Carriers Across All Sites
  • Data Center Space in HongKong and Singapore
  • 15+ MW Usable Power
  • AC/DC Options
  • Additional Power and Space Available
  • Managed Internet Infrastructure Available

Power

  • DC power A and B options available
  • 22,000 volt power feed to its three Square D Transformers fed to 480 batteries
  • Dual mission-critical 1000kVA redundant Uninterruptible Power Sources backed by 488 C &D flooded wet cell batteries
  • 2950 kilowatt Caterpillar Diesel Generator available within eight seconds of power failure
  • 12,500 gallon underground storage tank of diesel fuel
  •  Enough power to conduct business for four days without feed from Southern California Edison
  • IGBTs (Insulated Gate Bipolar Transistors) are combined with Pulse WidthModulation/Stepwave topology to provide reliable Operation